Dust in the Housing of Laying Hens: A case study
Santos, AMFurtado, DAMorais, FTLSilva, RCLopes Neto, JP
ABSTRACT As dust particles in laying poultry houses can have negative effects on health and on the environment, this study aimed to measure and compare dust concentrations in egg production sheds. The experiment was carried out in three sheds: Californian shed (G1), conventional closed shed with artificial ventilation (G2) and conventional closed shed without artificial ventilation (G3), and the birds housed were in the 22nd week of housing, in Cuité, Paraíba, Brazil. The dust particles were collected by a gravimetric pump, attached to the workers clothes, at the height of the respiratory zone, being removed at the end of the working day. Using the evaluation methodologies (total or breathable dust) according to NIOSH (1998), weighing was performed with sample concentration calculation, then the particle size was measured by microscopy according to the methodology described by Feret (Santos, 2001), with diameter of function obtained using an optical microscope, and particles classified by size (inhalable 100 µm, thoracic 25 µm and breathable 10 µm). Considering the limit of concentration x exposure time of 3.0 mg/m3, according to ACGIH (2013), the sheds had the following values: G1-0.98 mg/m3, G2-1.45 mg/m3 and G3-1.13 mg/m3. In the classification of particles by size, the highest frequencies were 83% thoracic, 13% inhalable, and 4% breathable. With the results presented, the implementation of the Respiratory Protection Program - PPR is suggested.
Texto completo